Resource Type

Journal Article 170

Year

2023 7

2022 12

2021 10

2020 14

2019 10

2018 6

2017 11

2016 7

2015 31

2014 12

2013 10

2012 6

2011 1

2010 6

2009 6

2008 7

2007 4

2005 3

2004 3

2001 1

open ︾

Keywords

smart grid 7

Smart grid 5

vector control 3

Artificial intelligence 2

Direct power control 2

Distributed optimization 2

active power 2

distribution grid 2

doubly fed induction generator (DFIG) 2

fuzzy logic controller 2

high voltage 2

phasor measurement unit (PMU) 2

power factor unity 2

power grid 2

reactive power 2

renewable energy 2

smart grid (SG) 2

total harmonic distortion (THD) 2

transient stability 2

open ︾

Search scope:

排序: Display mode:

Multiple target implementation for a doubly fed induction generator based on direct power control under unbalancedand distorted grid voltage

Heng NIAN,Yi-peng SONG

Frontiers of Information Technology & Electronic Engineering 2015, Volume 16, Issue 4,   Pages 321-334 doi: 10.1631/FITEE.1400170

Abstract: presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalancedand distorted grid voltage based on direct power control (DPC).Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional andvoltage nor complicated control reference calculation is required.and distorted grid voltage.

Keywords: Direct power control     Doubly fed induction generator     Unbalanced and distorted grid voltage     Vector proportional    

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under distortedvoltage conditions

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 212-220 doi: 10.1007/s11708-013-0284-4

Abstract: power and eliminate harmonics drawn from a thyristor rectifier feeding an inductive load (RL) under distortedvoltage conditions.The use of STF instead of classical extraction filters allows extracting directly the voltage and currentcontroller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage

Keywords: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy    

Experimental investigation and comparative study of inter-turn short-circuits and unbalanced voltage

Fatima BABAA, Abdelmalek KHEZZAR, Mohamed el kamel OUMAAMAR

Frontiers in Energy 2013, Volume 7, Issue 3,   Pages 271-278 doi: 10.1007/s11708-013-0258-6

Abstract: However, small unbalance in the supply voltage and/or in the machine structure that exists in any realIn this case, it is too difficult to distinguish between the current harmonics due to the supply voltageprovide the relationship between the inter-turn short-circuits in the stator winding and the supply voltage

Keywords: induction machines     fault indicator     inter-turn short-circuit fault     unbalance supply voltage    

Analysis and stabilization control of a voltage source controlled wind farm under weak grid conditions

Frontiers in Energy 2022, Volume 16, Issue 6,   Pages 943-955 doi: 10.1007/s11708-021-0793-5

Abstract: This paper investigates and discusses the interaction stability issues of a wind farm with weak gridthe wind turbines (WTs) are controlled by a new type of converter control strategy referred to as the voltageHowever, when it is applied to multiple WTs within a wind farm, its weak-grid performance regarding thestability margin quantification index, not only the interactions between the wind farm and the weak griddominant instability mode is more related to the interactions among the WTs rather than the typical grid-wind

Keywords: weak grids     voltage source (VS) control     wind turbine (WT)     stabilization control     wind farm     inertial    

Performance investigation of artificial intelligence based controller for three phase four leg shunt active filter

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

Frontiers in Energy 2015, Volume 9, Issue 4,   Pages 446-460 doi: 10.1007/s11708-015-0378-2

Abstract: paper, the choice of power quality compensator is a DSTATCOM which constitutes a three phase four leg voltagebalanced and sinusoidal source current from the supply mains that are nearly in phase with the supply voltage, compensates neutral current, and maintains voltage across the capacitor under unbalanced source and

Keywords: neutral current mitigation     total harmonic distortion (THD)     three phase four wire distribution system     unbalancedand/or distorted source    

Parameter identification of interconnected power system frequency after trip-out of high voltage transmission

Xuzhan ZHOU,Shanshan LIU,Mingkun WANG,Yiping DAI,Yaohua TANG

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 386-393 doi: 10.1007/s11708-014-0323-9

Abstract: Accurate modeling and parameters of high voltage (HV) grid are critical for stability research of systemThe results of this paper can provide reference for the stability research of HV power grid.

Keywords: high voltage (HV) grid     frequency stability parameter identification     primary frequency regulation (PFR    

THD reduction with reactive power compensation for fuzzy logic DVR based solar PV grid connected system

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

Frontiers in Energy 2014, Volume 8, Issue 4,   Pages 464-479 doi: 10.1007/s11708-014-0307-9

Abstract: Dynamic voltage restorer (DVR) is used to protect sensitive loads from voltage disturbances of the distributionIn this paper, a new control approach for the 200 kW solar photovoltaic grid connected system with perturbarray and maintains DC link voltage constant by changing modulation index of the converter.source converter (VSC) current and grid current with fast tracking of optimum operating point at unityStandards (IEEE-519/1547), stipulates that the current with THD greater than 5% cannot be injected into the grid

Keywords: fuzzy logic     maximum power point tracking (MPPT)     proportional integral (PI)     control     voltage restorer    

Reactive power deployment and cost benefit analysis in DNO operated distribution electricity markets with D-STATCOM

Atma Ram GUPTA,Ashwani KUMAR

Frontiers in Energy 2019, Volume 13, Issue 1,   Pages 86-98 doi: 10.1007/s11708-017-0456-8

Abstract: The aim of this paper is to analyze unbalanced radial distribution systems (UBRDS) with the distributionare D-STATCOM allocation in UBRDS with an objective of providing reactive power support to enhance voltage

Keywords: unbalanced distribution system     D-STATCOM     voltage sensitivity index     load models     load growth     distribution    

Power quality investigation of a solar PV transformer-less grid- connected system fed DVR

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 240-253 doi: 10.1007/s11708-014-0322-x

Abstract: This paper presents a single stage transformer-less grid-connected solar photovoltaic (PV) system withIn the absence of active input power, the grid-tied voltage source converter (VSC) is operated in a reactivepower generation mode, which powers the control circuitry, and maintains a regulated DC voltage to thewhich controls the grid side converter during single-phase to ground fault.array, and maintains the DC link voltage constant by changing the modulation index of the VSC.

Keywords: data-based maximum power point tracking (MPPT)     total harmonic distortion (THD)     proportional integral     control     voltage    

Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Frontiers in Energy 2023, Volume 17, Issue 3,   Pages 446-446 doi: 10.1007/s11708-022-0851-7

Abstract: solve this issue, this study sought to propose distributed energy management based on a three-phase unbalancedConsidering a three-phase unbalanced distribution network, the price signals were determined per phase

Keywords: distributed optimization     energy management     networked microgrids     three-phase distribution network     distributed energy resources    

switched fractional controller for performance improvement of single phase active power filter under unbalanced

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

Frontiers in Energy 2016, Volume 10, Issue 2,   Pages 203-212 doi: 10.1007/s11708-015-0381-7

Abstract: A novel controller is proposed to regulate the DC-link voltage of a single phase active power filter

Keywords: conventional PI controller     fractional calculus (FC)     total harmonic distortion (THD)     Oustaloup continuous approximation (OCA)     single phase active power filter (SPAPF)    

Experimental and theoretical investigations of the lateral vibrations of an unbalanced Jeffcott rotor

Ali ALSALEH, Hamid M. SEDIGHI, Hassen M. OUAKAD

Frontiers of Structural and Civil Engineering 2020, Volume 14, Issue 4,   Pages 1024-1032 doi: 10.1007/s11709-020-0647-y

Abstract: The current work experimentally explores and then theoretically examines the lateral vibrations of an unbalanced

Keywords: rotor-dynamics     Jeffcott rotor     lateral vibrations     Lagrange method     system-equivalent stiffness     sleeve bearings     oil film induced stiffness    

Recent advances toward high voltage, EC-free electrolytes for graphite-based Li-ion battery

Tong Zhang, Elie Paillard

Frontiers of Chemical Science and Engineering 2018, Volume 12, Issue 3,   Pages 577-591 doi: 10.1007/s11705-018-1758-z

Abstract: In the last years, many alternative electrolytes, aiming at allowing high voltage battery operation,Thus, we review here the high voltage, EC-free alternative electrolytes, focusing on those allowing the

Keywords: lithium-ion     electrolyte     solid electrolyte interphase     additives     high voltage     graphite    

Development and advances in modular multilevel converter based HVDC projects in China

Frontiers of Engineering Management   Pages 183-189 doi: 10.1007/s42524-022-0248-7

Abstract: . {{custom_ra.content}} . . . {{article.highlightEn}} . . . {{article.abstractEn}} . . . {{article.authorSummayEn}} . . . . .

Keywords: high voltage direct current     power converter     power systems     renewable energy     ultra-high voltage    

Optimal placement of PMUs for the smart grid implementation in Indian power grid—A case study

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

Frontiers in Energy 2013, Volume 7, Issue 3,   Pages 358-372 doi: 10.1007/s11708-013-0257-7

Abstract: The concept of smart grid (SG) can provide a highly reliable power system with optimized utilizationthe grid smarter and reliable.One of the important requirements for SG is the instantaneous monitoring of the voltage, current andpower flows at all buses in the grid.Since the voltage phasor values at the neighboring buses of a bus containing the PMU can be estimated

Keywords: phasor measurement units (PMUs)     smart grid (SG)     southern region Indian power grid (SRIPG)     integer linear    

Title Author Date Type Operation

Multiple target implementation for a doubly fed induction generator based on direct power control under unbalancedand distorted grid voltage

Heng NIAN,Yi-peng SONG

Journal Article

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under distortedvoltage conditions

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Journal Article

Experimental investigation and comparative study of inter-turn short-circuits and unbalanced voltage

Fatima BABAA, Abdelmalek KHEZZAR, Mohamed el kamel OUMAAMAR

Journal Article

Analysis and stabilization control of a voltage source controlled wind farm under weak grid conditions

Journal Article

Performance investigation of artificial intelligence based controller for three phase four leg shunt active filter

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

Journal Article

Parameter identification of interconnected power system frequency after trip-out of high voltage transmission

Xuzhan ZHOU,Shanshan LIU,Mingkun WANG,Yiping DAI,Yaohua TANG

Journal Article

THD reduction with reactive power compensation for fuzzy logic DVR based solar PV grid connected system

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

Journal Article

Reactive power deployment and cost benefit analysis in DNO operated distribution electricity markets with D-STATCOM

Atma Ram GUPTA,Ashwani KUMAR

Journal Article

Power quality investigation of a solar PV transformer-less grid- connected system fed DVR

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

Journal Article

Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Journal Article

switched fractional controller for performance improvement of single phase active power filter under unbalanced

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

Journal Article

Experimental and theoretical investigations of the lateral vibrations of an unbalanced Jeffcott rotor

Ali ALSALEH, Hamid M. SEDIGHI, Hassen M. OUAKAD

Journal Article

Recent advances toward high voltage, EC-free electrolytes for graphite-based Li-ion battery

Tong Zhang, Elie Paillard

Journal Article

Development and advances in modular multilevel converter based HVDC projects in China

Journal Article

Optimal placement of PMUs for the smart grid implementation in Indian power grid—A case study

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

Journal Article